A REAL EDITING QUESTION
Should HDR use PQ or HLG, and which luminance values are actually correct?
Choose according to the recipient's requirements and your monitoring. PQ defines an absolute relationship between signal and reference-display luminance; HLG uses a relative scene representation and display adaptation to nominal screen luminance. YouTube accepts both in correctly encoded 10- or 12-bit files with accurate metadata.
1000 nits is a possible mastering target, not a mandatory property of every HDR video. 203 nits is nominal HDR reference white under stated conditions. 10000 nits is the upper limit of PQ encoding, not a target for a white title.
Before you start
- Establish whether the recipient requires PQ, HLG, HDR10, HDR10+ or Dolby Vision. These names do not specify the same set of requirements.
- Record the target luminance, viewing conditions, container, codec, bit depth, colour tags and signal-range requirements.
- Identify camera inputs before selecting the output. Sony Log and Apple Log do not become HLG because the deliverable is HDR.
- Prepare bright detail, a face, gradient, dark shot and white graphics for a short test.
Start with the destination, not viewer brightness
Without a specification, identify the viewing destination and a reliable assessment method. Neither PQ's larger numerical range nor HLG's adaptability removes the need to verify the finished image.
PQ is a transfer function; HDR10 adds delivery conditions. HLG is not synonymous with every Dolby Vision file. Follow the entire broadcaster or service specification.
If the columns do not fit, scroll the table horizontally.
| Question | PQ | HLG |
|---|---|---|
| What does the signal describe? | An absolute luminance relationship through the ST.2084 EOTF | A relative scene signal with the HLG display system |
| When should it be chosen? | The recipient requires PQ/HDR10, or the process centres on a defined mastering luminance | The recipient requires HLG, or the production and broadcast chain is designed for HLG |
| What matters at the display? | Correct PQ interpretation, target range and tone-mapping behaviour | HLG interpretation, nominal luminance and system gamma for the viewing conditions |
| YouTube | Supported; PQ has provisions for mastering metadata and MaxCLL/MaxFALL | Supported; correct HLG and Rec.2020 tags are still required |
References: ITU-R BT.2100-3 — HDR television parameters; ITU-R BT.2408-9 — HDR operational practice; YouTube Help — Upload High Dynamic Range videos
Rec.2020 and Rec.2100 do not replace each other
Gamut describes colour; the transfer function relates signal to light. Rec.2100 defines PQ/HLG HDR using Rec.2020 primaries. Rec.2020 alone does not identify the transfer function.
Use Rec.2020 with Rec.2100 ST2084 or Rec.2100 HLG in Resolve's separate fields. Rec.709 Gamma 2.4 is SDR. All three masters can share internal DWG/Intermediate.
P3-limited colours can be encoded correctly in Rec.2020. Simply labelling unconverted P3 RGB values as Rec.2020 makes the receiver interpret their coordinates incorrectly.
References: ITU-R BT.2100-3 — HDR television parameters; Blackmagic — Resolve 21.1: RCM, metadata and output; YouTube Help — Upload High Dynamic Range videos
Separate 100, 203, 1000 and 10000 nits
BT.2408-9 associates nominal diffuse/graphics white with approximately 58% PQ or 75% HLG. For HLG, the corresponding 203 cd/m² assumes a display with a nominal 1000 cd/m² peak. A different HLG display luminance changes the light result even though the signal value remains the same.
These percentages describe normalised signal, not every scope scale. The report allows creative variation and differing skin levels. Use reference white to coordinate graphics and conversions, then inspect HDR and SDR instead of forcing every shot to one number.
If the columns do not fit, scroll the table horizontally.
| Value | Meaning | What it does not require |
|---|---|---|
| 100 nits | A conventional nominal SDR reference-display target | It does not limit the physical brightness of every consumer SDR display |
| 203 nits | Nominal HDR Reference White in BT.2408 | It does not set one luminance for skin, a grey card and every white object |
| 1000 nits | An example PQ mastering target and nominal HLG reference display | It does not mean that the entire image must be brighter than SDR |
| 10000 nits | The upper limit of absolute PQ encoding | It is not a mandatory mastering or display luminance |
References: ITU-R BT.2100-3 — HDR television parameters; ITU-R BT.2408-9 — HDR operational practice
Set up viewing and understand the measurement
Align the complete viewing path
Resolve output, interface/OS mode, receiving display and its PQ/HLG mode must agree. Avoid unpredictable automatic mode changes during comparison and record viewing conditions.
Check: Interface brightness is not used as a substitute for HDR mastering, and any additional display tone mapping is understood.
Use appropriate measurements
Studio scopes offer nit/cd/m² scales. In Free, use available signal/code-value scopes and suitable external analysis. A code value needs a known transfer function and scale to describe luminance.
Check: The same digital waveform height is not claimed to mean the same luminance in PQ and HLG.
Check graphics and extremes
Inspect text, reflections, lamps, faces and shadows. Peaks beyond the display's capability cannot be visually approved unseen. Check important detail after SDR conversion too.
Check: The image, as well as the HDR labels, passes review under the agreed viewing conditions.
References: ITU-R BT.2408-9 — HDR operational practice; Blackmagic — Studio: Professional HDR Scopes; Blackmagic — Resolve 21.1: HLG and HDR Light Level Report
Change the actual output transform in Resolve
Keep the shared foundation
In RCM, retain DaVinci Wide Gamut / DaVinci Intermediate and the chosen working luminance. Use separate timelines or Studio trims for multiple masters so that each version has an explicit output.
Check: Changing delivery format does not alter source interpretation or the mathematical environment of an existing grade.
Assign the HDR output
With Use separate color space and gamma, set Output Color Space → Rec.2020. For PQ choose Output Gamma → Rec.2100 ST2084; for HLG choose Rec.2100 HLG. The combined Rec.2100 HLG (Scene) option has a different purpose and is not interchangeable with the ordinary display-output choice.
Check: The recipient expects the selected EOTF, and tone mapping and target luminance match the master.
Align the encoded file
In Deliver, choose supported 10- or 12-bit encoding for the brief and check Color Space Tag and Gamma Tag. Renaming PQ tags to HLG does not recalculate pixels: return to the Output transform and render a new sample to change format.
Check: Metadata describes the actual result. The HDR mastering is for checkbox does not replace an image transform either.
References: Blackmagic — Resolve 21.1: RCM, metadata and output; Blackmagic — Resolve 21.1: HLG and HDR Light Level Report; Blackmagic — Resolve 21.1: Rec.2100 ST2084 label; YouTube Help — Upload High Dynamic Range videos
Identify the particular iPhone HDR case
Apple TN3145 specifies Dolby Vision Profile 8.4 as HEVC Main10, BT.2020 primaries/matrix and BT.2100 HLG transfer. Its compatible base is HLG. Other iPhone files may be SDR, Apple Log or processed exports; identify them individually.
A confirmed HLG input can enter the shared working space and leave as PQ or SDR. Dolby Vision in the original does not guarantee that an export preserves dynamic metadata or authors a new Dolby Vision master.
Apple's ambient viewing metadata can affect playback. If a transcode changes brightness, inspect pixels, tags and viewing conditions before regrading. Global Gamma 2.2 is not a universal fix.
References: Apple — TN3145: HDR video metadata; Blackmagic — Resolve 21.1: RCM, metadata and output
Verify delivery and the automatic SDR version
YouTube requires Rec.2020 primaries/non-constant luminance matrix, PQ or HLG, and 10- or 12-bit encoding. Recommended codecs include HEVC, AV1 and VP9 Profile 2; check export availability. An HDR filename proves none of these properties.
For PQ, YouTube specifies ST.2086 mastering-display metadata and MaxCLL/MaxFALL. Do not copy a monitor's advertised peak into content statistics as though the film had been measured. YouTube uses defaults when information is absent; that is not validation of the master.
After processing, inspect a short upload in HDR and the platform-generated SDR version. Automatic conversion can change faces, graphics and highlights. Your own SDR trim remains a separate master.
References: YouTube Help — Upload High Dynamic Range videos; Blackmagic — Resolve 21.1: HLG and HDR Light Level Report; ITU-R BT.2408-9 — HDR operational practice
FIND THE CAUSE
If the result looks wrong
PQ looks dark and washed out.
Possible cause. Possible SDR interpretation, wrong input or a double transform.
What to check. Verify the transfer tag, viewing mode and entire Input → Timeline → Output path before raising overall exposure.
HLG looks different on two displays.
Possible cause. Nominal luminance, system gamma, surround or display processing differs.
What to check. Align reference conditions and confirm HLG mode. Do not treat 75% signal as a fixed 203 nits on every display.
White titles are uncomfortably bright.
Possible cause. Graphics were mapped towards HDR peak instead of the agreed graphics white, or SDR was converted incorrectly.
What to check. Check the graphics path, reference white and real viewing. Do not darken the entire film to solve a title problem.
YouTube offers no HDR after processing completes.
Possible cause. The file may be 8-bit or have incorrect tags, encoding or transfer characteristics.
What to check. Inspect the uploaded file's bit depth, primaries, transfer and matrix, then repeat a short test.
Relabelling HDR10/PQ as HLG changes the image incorrectly.
Possible cause. Only metadata changed; pixel values were not converted.
What to check. Return to the project, perform an actual PQ ↔ HLG conversion, assess the image and export again.
An iPhone export looks brighter than the original.
Possible cause. Input, HDR metadata or the application's ambient adaptation may have changed.
What to check. Confirm the profile and HLG base, compare pixels and metadata, and investigate Apple playback before regrading.
A result you can verify
Checked: 0 / 10
Marks stay on this page while it is open. Check the file yourself before marking an item.
Questions that come up next
Can HLG be viewed on SDR with no compromise?
HLG has limited compatibility with legacy systems, but does not guarantee an approved SDR appearance. Gamut, luminance and device processing still matter. For a controlled SDR result, perform a conversion and trim.
Does HLG need no metadata at all?
HLG does not require the same mastering-metadata scheme for luminance adaptation as PQ delivery. The file must still identify its gamut, transfer and matrix correctly. Particular ecosystems may use additional information, such as Apple's ambient viewing metadata.
If the monitor is 1000 nits, should MaxCLL be 1000?
No. Mastering-display capabilities and content statistics are different information. MaxCLL and MaxFALL describe the video itself; establish them through suitable analysis, not the display specification.
Which is better for YouTube: PQ or HLG?
YouTube accepts both. Choose the option you can correctly produce, assess and describe with metadata. Existing HLG footage may simplify a particular workflow, but does not remove the need to verify the processed upload.
Can a tag turn finished SDR into HDR?
No. A tag neither expands dynamic range nor changes pixels. Deliberate SDR → HDR conversion is possible, but it cannot restore information absent from the SDR file.
Sources and review scope
Product documentation and standards are linked to the relevant steps above. Where settings depend on a camera, application build or delivery specification, use that exact combination.
- ITU-R BT.2100-3 — HDR television parameters
February 2025; printed pp. 3–8, PDF pp. 5–10: colorimetry, PQ, HLG, reference viewing and system gamma.
- ITU-R BT.2408-9 — HDR operational practice
March 2026; printed pp. 6–13, PDF pp. 8–15: 203 nits, 58% PQ / 75% HLG, monitoring conditions and caveats.
- Blackmagic — Resolve 21.1: RCM, metadata and output
September 2026; pp. 234–244 and 4120: separate controls, DRT, HDR mastering and tags versus transforms.
- Blackmagic — Resolve 21.1: HLG and HDR Light Level Report
Pp. 281–282: HLG options and the separate Studio designation for HDR Light Level Report.
- Blackmagic — Resolve 21.1: Rec.2100 ST2084 label
P. 4276 confirms the gamma label in separate controls. The chapter's immersive P3 setup is not reused for our Rec.2020 recipe.
- Blackmagic — Studio: Professional HDR Scopes
Checked 29 November 2026; nit/cd/m² scales are a Studio feature.
- Apple — TN3145: HDR video metadata
Revised 12 December 2023; checked 29 November 2026. Dolby Vision Profile 8.4, the HLG base and ambient viewing environment.
- YouTube Help — Upload High Dynamic Range videos
Checked 29 November 2026: 10/12-bit, Rec.2020, PQ/HLG, metadata and automatic SDR conversion.
What still needs your own test
- Standards and interface settings were checked against documentation, without native Resolve execution, rendering, a YouTube upload or display measurement. Acceptance requires a short test of your file and real target playback.
- This article does not replace a broadcaster specification or an authorised Dolby Vision/HDR10+ workflow. Unknown monitoring or unverified measurements cannot establish final HDR luminance and image quality.