After this lesson
- Add a technical time label.
- State exactly which count it displays.
- Check fps, offsets and minute boundaries.
Before you start
- Composition
- A separate Fusion Composition. 1920×1080, square pixels, 25 fps.
- Parameter
- Text1 → Styled Text → Time Code
- Range
- Start at comp.RenderStart. Reference frames are local unless stated otherwise.
Time Code creates a text time display. It helps with review versions and animation checks but does not guarantee automatic camera-source timecode retrieval.
Connecting and choosing display fields
Add Time Code to Text+ Styled Text. In Modifiers, choose the required fields: hours, minutes, seconds, frames and other available options.
For a frame counter, keep the corresponding field. For conventional timecode, check the frame rate and format. The label must serve its purpose rather than merely look technical.
Offset and frame rate
Start Offset aligns the initial display with the required count. Check second and minute boundaries. For fractional rates, investigate drop-frame separately if needed.
Drop-frame does not remove video frames. It is a timecode numbering rule. Do not replace it with arbitrary rounding of seconds*fps.
Technical verification
If the client needs source-file or timeline timecode, verify that exact data source. Consider Resolve’s Data Burn-In for review copies.
Compare the label with the reference Resolve display at several points, including minute boundaries. This is especially important after retiming, trimming or changing the composition start.
Composition timecode and source timecode differ
Text+ with Time Code is a convenient technical label, but its count is not automatically camera timecode. The composition and edit timeline may have different starts. State what the label shows: local frame number, composition time or an agreed count with an offset.
If source-file timecode is required, verify the metadata source and Resolve-level workflow first. Adding Offset to local time is valid only when the source relationship is known and has not been broken by retiming.
One check at zero is insufficient
Compare the start, one second later, a minute boundary and the end of a long clip. At 29.97/59.94, agree on drop-frame or non-drop-frame separately: timecode format and actual frame count are different concepts. Do not change separators merely to resemble a reference visually.
Keep technical labels on a separate Merge branch for client previews, so they can be disabled before master export. Embedding burn-in directly in creative text increases the risk of leaving it in the final output.
Parameters and ranges
| Parameter | What it changes | Example / check |
|---|---|---|
| Styled Text → Time Code | Source of the text label. | Not a numeric Size modifier. |
| Format | Which parts of the count are shown. | Frames or hours/minutes/seconds/frames. |
| Start Offset | The agreed starting offset. | Checked against the intended reference. |
| fps / DF-NDF | Time contract. | Especially important for fractional frame rates. |
USE IN A COMPOSITION
Build it in Fusion
Text1 → Styled Text → Time Code
Solid lines are node connections in the Flow. A dashed line is a parameter dependency configured in the Inspector.
Connections by port and parameter4
Color is determined by the destination input. Dashed connections are configured in the Inspector; they do not add an RGBA wire to the Flow.
Assembly steps
- Add a separate Text+ for the technical label.
- Choose Time Code from the Styled Text menu and open Modifiers.
- Decide whether to display a local count or an agreed timecode with an offset.
- Set the format and Start Offset. Verify the frame rate.
- Compare with the intended Resolve reference at the start, after one second and at a minute boundary.
- Connect the label through a separate Merge so it can be disabled for final export.
Expected result. The text shows the agreed count; its time source has been verified rather than assumed.
Checkpoints
| When / what to check | Expected | Why check it |
|---|---|---|
| Start | Matches the chosen reference | Checks the offset. |
| Twenty-five frames later at 25 fps | One second has elapsed | Checks the rate. |
| Minute boundary | Correct field rollover | Checks the format. |
| Final output without burn-in | Technical branch disabled | Checks the master file. |
Errors and troubleshooting
The label does not match the camera
The modifier may show composition time rather than source metadata.
Error at a minute boundary
Check fps, drop-frame and offset; do not fix it with an arbitrary multiplier.
Independent exercise
Can any text counter of seconds be called SMPTE timecode?
Show the solution and explanation
No. It needs correct frame numbering, rate, format and a defined time source.
Continue learning
Official sources
An original educational walkthrough. The browser model explains the principle but does not run Fusion. Control placement depends on the version; save the original composition before replacing a parameter's control source.