Skip to content
VIDEOMONTAZHERDAVINCI RESOLVE · VIDEO · AI

FUSION · Modifiers

Time Code: frame and timecode labels

Composition-time display, offsets and the difference from source-file metadata.

Fusion / DaVinci Resolve 20–21

After this lesson

  • Add a technical time label.
  • State exactly which count it displays.
  • Check fps, offsets and minute boundaries.

Before you start

Composition
A separate Fusion Composition. 1920×1080, square pixels, 25 fps.
Parameter
Text1 → Styled Text → Time Code
Range
Start at comp.RenderStart. Reference frames are local unless stated otherwise.

Time Code creates a text time display. It helps with review versions and animation checks but does not guarantee automatic camera-source timecode retrieval.

Connecting and choosing display fields

Add Time Code to Text+ Styled Text. In Modifiers, choose the required fields: hours, minutes, seconds, frames and other available options.

For a frame counter, keep the corresponding field. For conventional timecode, check the frame rate and format. The label must serve its purpose rather than merely look technical.

Offset and frame rate

Start Offset aligns the initial display with the required count. Check second and minute boundaries. For fractional rates, investigate drop-frame separately if needed.

Drop-frame does not remove video frames. It is a timecode numbering rule. Do not replace it with arbitrary rounding of seconds*fps.

Technical verification

If the client needs source-file or timeline timecode, verify that exact data source. Consider Resolve’s Data Burn-In for review copies.

Compare the label with the reference Resolve display at several points, including minute boundaries. This is especially important after retiming, trimming or changing the composition start.

Composition timecode and source timecode differ

Text+ with Time Code is a convenient technical label, but its count is not automatically camera timecode. The composition and edit timeline may have different starts. State what the label shows: local frame number, composition time or an agreed count with an offset.

If source-file timecode is required, verify the metadata source and Resolve-level workflow first. Adding Offset to local time is valid only when the source relationship is known and has not been broken by retiming.

One check at zero is insufficient

Compare the start, one second later, a minute boundary and the end of a long clip. At 29.97/59.94, agree on drop-frame or non-drop-frame separately: timecode format and actual frame count are different concepts. Do not change separators merely to resemble a reference visually.

Keep technical labels on a separate Merge branch for client previews, so they can be disabled before master export. Embedding burn-in directly in creative text increases the risk of leaving it in the final output.

Parameters and ranges

ParameterWhat it changesExample / check
Styled Text → Time CodeSource of the text label.Not a numeric Size modifier.
FormatWhich parts of the count are shown.Frames or hours/minutes/seconds/frames.
Start OffsetThe agreed starting offset.Checked against the intended reference.
fps / DF-NDFTime contract.Especially important for fractional frame rates.

USE IN A COMPOSITION

Build it in Fusion

Text1 → Styled Text → Time Code

FUSION / FLOWNodes and parameter control
100%
ImageControl in the InspectorScroll or drag the graph. Choose “Fit” to see all of it.
Solid lines are node connections in the Flow. A dashed line is a parameter dependency configured in the Inspector. A solid arrow's color matches its destination input. Modifiers are shown separately from the Flow.Background1.Output → Merge1.BackgroundMerge1.Output → MediaOut1.InputText1.Output → Merge1.Foregroundcontrol.Value → Text1.Styled TextText1 · Image node · FlowT+Text1Text+Styled TextStyled Text · an Inspector parameter, not an image portBackground1 · Image node · Flow▧Background1BackgroundMerge1 · Image node · Flow⊕Merge1MergeMediaOut1 · Image node · Flow↗MediaOut1MediaOutTimeCode1 · Modifier · InspectorMODIFIERSTimeCode1Time Code
BackgroundImageForegroundParameter · Inspector
Select a node or a colored arrow

Solid lines are node connections in the Flow. A dashed line is a parameter dependency configured in the Inspector.

Connections by port and parameter4

Color is determined by the destination input. Dashed connections are configured in the Inspector; they do not add an RGBA wire to the Flow.

Assembly steps

  1. Add a separate Text+ for the technical label.
  2. Choose Time Code from the Styled Text menu and open Modifiers.
  3. Decide whether to display a local count or an agreed timecode with an offset.
  4. Set the format and Start Offset. Verify the frame rate.
  5. Compare with the intended Resolve reference at the start, after one second and at a minute boundary.
  6. Connect the label through a separate Merge so it can be disabled for final export.

Expected result. The text shows the agreed count; its time source has been verified rather than assumed.

Checkpoints

When / what to checkExpectedWhy check it
StartMatches the chosen referenceChecks the offset.
Twenty-five frames later at 25 fpsOne second has elapsedChecks the rate.
Minute boundaryCorrect field rolloverChecks the format.
Final output without burn-inTechnical branch disabledChecks the master file.

Errors and troubleshooting

The label does not match the camera

The modifier may show composition time rather than source metadata.

Error at a minute boundary

Check fps, drop-frame and offset; do not fix it with an arbitrary multiplier.

Independent exercise

Can any text counter of seconds be called SMPTE timecode?

Show the solution and explanation

No. It needs correct frame numbering, rate, format and a defined time source.

Continue learning

Official sources

Blackmagic Design · Text+ and text modifiersGenerator Nodes → Text+: Follower, Character Level Styling, Text Timer and Time Code.

An original educational walkthrough. The browser model explains the principle but does not run Fusion. Control placement depends on the version; save the original composition before replacing a parameter's control source.