Skip to content
VIDEOMONTAZHERDAVINCI RESOLVE · VIDEO · AI

FUSION · Modifiers

Probe: an image drives a parameter

Measure a channel or region, map brightness and avoid feedback loops.

Fusion / DaVinci Resolve 20–21

After this lesson

  • Turn an image measurement into a controlled number.
  • Choose point or region sampling.
  • Avoid feedback from the measured result.

Before you start

Composition
A separate Fusion Composition. 1920×1080, square pixels, 25 fps.
Parameter
Transform1 → Size; Probe reads an independent Background
Range
Start at comp.RenderStart. Reference frames are local unless stated otherwise.

Probe connects an image to numeric control: for example, brightness in a selected region can drive scale or effect intensity. It is a measuring tool, not automatic object recognition.

What and where to measure

Assign Image to Probe, choose a channel and a sampling position or region. Start with a simple Background of known colors rather than a complex video clip.

Red, alpha and luminance produce different signals. A transparent region may still contain color data, so choose the channel to match the task.

Mapping the measurement

Input scaling and output values map a measurement to a useful range. For example, black can mean scale 0.8 and white 1.2. Check these two reference points first.

HDR and scene-linear values need not stay within 0…1. Define behavior above white and when sampling coordinates leave the image.

Signal stability

A single pixel can produce a noisy result. Where region sampling is available, choose suitable aggregation and check that important details are not lost.

Do not measure an effect’s output and immediately use that measurement to set the same effect’s intensity if this creates a cycle. Use an independent source branch.

Calibrate with black, gray and white

Use a separate test Background and one clear channel. For a linear check, set input range 0…1, Black Value=0.8 and White Value=1.2. Expect 0.8 for black, 1.0 for numeric gray 0.5, and 1.2 for white. The middle input must be 0.5 in the computed image, not merely look gray in the Viewer.

Replace the Background with real video only after calibration. Color transforms, HDR range, alpha and the selected channel change what the measurement means. The sampling node’s graph position matters as much as its settings.

A point and a regional average behave differently

One pixel is sensitive to noise, fine details and subpixel movement. Probe Rectangle with Average usually provides a steadier regional measurement. Minimum and Maximum answer a different question: the darkest or brightest value, not the average level.

The measurement source must not depend on the parameter Probe controls. Measuring an already amplified result to control its own amplification creates a cycle. Branch off an independent signal before the driven effect. Test regions outside the image and set a meaningful Out of Image Value.

Parameters and ranges

ParameterWhat it changesExample / check
PositionMeasurement position.Start at the center.
Probe Rectangle / EvaluationRegion and pixel aggregation method.Average for a mean value.
Black Value / White ValueOutputs at the input-range endpoints.0.8 and 1.2.
Out of Image ValueResult outside the image.Choose a safe value for the consumer.

USE IN A COMPOSITION

Build it in Fusion

Transform1 → Size; Probe reads an independent Background

FUSION / FLOWNodes and parameter control
100%
ImageControl in the InspectorScroll or drag the graph. Choose “Fit” to see all of it.
Solid lines are node connections in the Flow. A dashed line is a parameter dependency configured in the Inspector. A solid arrow's color matches its destination input. Modifiers are shown separately from the Flow.control.Value → Transform1.SizeText1.Output → Transform1.InputTransform1.Output → MediaOut1.InputBackgroundMeasure.Output → control.Image / SourceProbe1 · Modifier · InspectorMODIFIERSProbe1ProbeText1 · Image node · FlowT+Text1Text+Transform1 · Image node · FlowƒTransform1TransformSizeSize · an Inspector parameter, not an image portMediaOut1 · Image node · Flow↗MediaOut1MediaOutBackgroundMeasure · Image node · Flow▧BackgroundMeasureBackground
Parameter · InspectorImageExternal source
Select a node or a colored arrow

Solid lines are node connections in the Flow. A dashed line is a parameter dependency configured in the Inspector.

Connections by port and parameter4

Color is determined by the destination input. Dashed connections are configured in the Inspector; they do not add an RGBA wire to the Flow.

Measurement uses an independent branch to avoid a dependency cycle.

Assembly steps

  1. Create a separate measurement Background that is not connected to the controlled branch’s final output.
  2. Add Probe to the object Transform’s Size and assign that Background as the measurement source.
  3. Choose a clear measurement channel; set Scale Input 0…1, Black Value=0.8 and White Value=1.2.
  4. Set Background numeric levels to 0, 0.5 and 1 in turn and compare Size.
  5. Switch from a point to a small region, then compare Average with Minimum/Maximum on a nonuniform source.
  6. Connect a real image only after calibration. Verify that the measured branch does not depend on Size.

Expected result. An image drives the parameter through a clear measurement and mapping.

Checkpoints

When / what to checkExpectedWhy check it
Input 00.8Lower calibration point.
Input 0.51.0Middle of the linear mapping.
Input 11.2Upper calibration point.
Region outside the imageConfigured fallback valueNo arbitrary jump in scale.

INTERACTIVE EXAMPLE

Change a parameter. Compare the result.

INTERACTIVE EXAMPLE

Probe: brightness becomes a number

CONTROLLED INPUTIndependent Background → Probe → Transform.Size
RESULT IN THE FRAMETEACHING PREVIEW
Level: 0.5
F
Size: 1
The measurement source and controlled object are separate branches
Probe outputMeasured level
0.7511.2500.51
CALCULATION CHECK0.8 + (1.2 − 0.8) × 0.5 = 1

Calibrate a uniform image: Scale Input 0…1. Its measured level maps to the range from Black Value to White Value.

RESULTSize = 1
CHECK THE DEPENDENCY

The initial levels 0, 0.5 and 1 give Size values 0.8, 1 and 1.2. Swap Black Value and White Value to invert the response.

The gray square represents the source's numeric level. It is not an on-screen sRGB measurement: check color management, HDR and Probe's sampling region in Fusion.

Errors and troubleshooting

Size jitters strongly

Check the selected channel, sampling area and source noise.

A cyclic dependency appeared

Feed Probe from an independent branch before the controlled effect.

Independent exercise

Why should an arbitrary RGB channel not drive transparency without checking?

Show the solution and explanation

RGB and alpha describe different properties; a transparent pixel can have nonzero color. Choose the channel according to the task.

Continue learning

Official sources

Blackmagic Design · Fusion Reference ManualThe chapter “Using Modifiers, Expressions, and Custom Controls”. Page numbers depend on the PDF edition.
Blackmagic Design · Modifiers referenceThe Modifiers section. Available commands depend on the input type and Fusion version.

An original educational walkthrough. The browser model explains the principle but does not run Fusion. Control placement depends on the version; save the original composition before replacing a parameter's control source.