After this lesson
- Set a variation range with Minimum/Maximum.
- Separate range from smoothing.
- Check frame edges and readability.
Before you start
- Composition
- A separate Fusion Composition. 1920×1080, square pixels, 25 fps.
- Parameter
- A compatible Transform input
- Range
- Start at comp.RenderStart. Reference frames are local unless stated otherwise.
The Shake modifier drives a compatible input. It differs from the separate Camera Shake effect, which processes an image with its own settings.
Choose a minimal test
Apply Shake to a compatible input through the available modifier menu. Start with a small range and slow variation. For angle, use small degree values; for position, use very small normalized offsets.
Specific fields and availability depend on input type and version. If the modifier is absent, do not substitute a similarly named image effect; investigate Perturb or a simple procedural expression.
Give randomness a purpose
Decide what you are imitating: camera jitter, mechanical vibration or an anxious title. Their amplitude, speed and distribution across axes differ.
Readable text usually needs variation in only one parameter. Randomly changing Center, Angle and Size together can quickly become uncontrolled.
Edges and repeatability
Shifting a whole image can reveal frame edges. Allow overscan or deliberately choose edge handling. For transparent titles, check image boundaries and cropping.
Fix the seed where available. Compare identical frames across repeated playback; do not judge the motion from one fortunate pass.
Minimum and maximum are absolute values
For additional Angle, use Minimum=-2 and Maximum=2 around zero. For Size, an equivalent idea is 0.98…1.02, not −0.02…0.02: scale should vary around one. For Center, the base is usually around 0.5. Do not transfer identical numbers between parameters with different units.
Start with equal Minimum and Maximum, such as 0 for Angle, collapsing the range to a constant. Then spread the limits symmetrically. This reveals how the motion relates to the selected range.
Smoothing does not replace range limits
Smoothness changes how variation evolves, not its amplitude. If the text moves too far, narrow Minimum/Maximum first. Then tune smoothness so small high-contrast details do not tremble. Random Seed fixes the particular variation.
When shaking an entire image, check for empty edges. A slight scale increase can conceal them but crops the composition and does not solve large displacement. For interface titles, it is usually better to shake an individual branch or decorative element than the whole background.
Parameters and ranges
| Parameter | What it changes | Example / check |
|---|---|---|
| Minimum / Maximum | Lower and upper value limits. | −2…2 for Angle; 0.98…1.02 for Size. |
| Smoothness | Smoothness of change. | Adjust after establishing the range. |
| Random Seed / Reseed | Selects a repeatable variation. | Do not change it after approval without another check. |
| Lock X/Y | Links coordinate settings on a positional input. | A numeric Angle has no corresponding axes. |
USE IN A COMPOSITION
Build it in Fusion
A compatible Transform input
Solid lines are node connections in the Flow. A dashed line is a parameter dependency configured in the Inspector.
Connections by port and parameter4
Color is determined by the destination input. Dashed connections are configured in the Inspector; they do not add an RGBA wire to the Flow.
Assembly steps
- Add Transform_Detail to the object branch rather than the entire background.
- On Angle, choose Modify With → Shake.
- In Modifiers, set Minimum=0 and Maximum=0: there should be no extra rotation.
- Change the limits to −2 and 2. Adjust Smoothness without changing the range.
- Choose Random Seed and request the same frame again after scrubbing.
- Compare the result full-screen. For Size, use a range around 1 rather than copying angle values.
Expected result. The result is controlled variation rather than random destruction of the composition.
Checkpoints
| When / what to check | Expected | Why check it |
|---|---|---|
| Minimum=Maximum=0 | Angle=0 | Diagnostic constant. |
| Minimum=-2, Maximum=2 | A small deviation around zero | Neither extreme is guaranteed to be reached during every short segment. |
| Repeat a frame | The same value with the same seed | Repeatability. |
| Full frame | No empty edges; readable text | Judge the result by more than the numeric value. |
Errors and troubleshooting
Black edges appeared
Allow more source-image coverage or adjust edge handling.
Only Camera Shake appears in the list
That is a different tool; check the parameter menu rather than the effects catalog.
Independent exercise
What should be fixed first when shaking makes a title difficult to read?
Show the solution and explanation
Reduce amplitude, then assess speed. If necessary, keep movement on only one coordinate or Angle.
Continue learning
Official sources
An original educational walkthrough. The browser model explains the principle but does not run Fusion. Control placement depends on the version; save the original composition before replacing a parameter's control source.